PVC sewer pipe 110 mm for the installation of individual systems

When creating communication networks for drainage, it is allowed to use conductive elements made of various materials. However, PVC sewer pipe 110 mm is very popular, as it is ideal for the installation of individual systems. The material used has good performance, and the presented diameter allows for normal throughput.

PVC sewer pipe 110 mm

Product Benefits

Using sewer PVC pipes of 110 mm for an autonomous network, it is possible to achieve high-quality drainage of domestic drains from a private house. Systems made from them serve a long time without additional maintenance. Of the main advantages, it is necessary to highlight:

  • resistance to biological and chemical influences;
  • sufficient strength;
  • low cost;
  • the availability of components;
  • easy installation method.

During the work, the elements are connected by means of sockets, which are located at their ends. This option is very convenient. The joints are water resistant due to special gaskets and hermetic means.

Sewer pipes PVC 110 mm

Elements for outdoor use

From the street side, soil acts on fragments of the sewage system. Therefore, PVC sewer pipes 110 mm external are used there. They have a multilayer structure that can withstand the pressure of the soil. They can be distinguished from other peers in orange.

For installation under normal conditions, products marked SN4 are used, the purpose of which is to install external networks with a normal load. Such elements are able to withstand the movement of the soil and the impact of small vehicles.

Sewer pipes PVC 110 mm outer

Indoor Products

Also indispensable for installation in the premises of the pipe sewer PVC 110 mm. The internal laying method does not imply additional mechanical impact, therefore, achieving too high strength characteristics during manufacturing does not make much sense. Such elements are single-layer and, as a rule, have a gray color.

Set of component parts

The consumer is invited to purchase 110 mm PVC sewer pipes and fittings that allow the connection of conductive fragments to each other. The standard set of additional elements makes it possible to arrange systems of different configurations.

Change the movement of fluid inside the pipeline using a special outlet. The angle of rotation of this part usually varies in a certain range. Joining of additional elements is carried out by means of tees. Peripheral branching of parts is necessary to create complex sewer networks.

The audit is intended to provide access to the interior of the pipelines. This may be required for treatment activities. If necessary, the plastic cover is easily unscrewed, after which an analysis is made for the presence of blockages in the system.

To combine 110 mm PVC sewer pipes with elements having a different diameter, a reducer is used. However, in most cases they do without installing it. The plug is used to close openings at the ends of pipelines.

To install the bends directly in two planes, special crosses are purchased. The adjoining hole can be located on the left or on the right, so that the conductive elements to plumbing fixtures can be placed in the optimal position.

PVC sewer pipes 110 mm and fittings

Sealing system at joints

In order for the 110 mm PVC sewer pipe to be hermetically joined to the rest of the system fragments, rubber rings must be used. Using these seals, it is possible to provide reliable sealing at the joints. Such gaskets are able to withstand the effects of many aggressive substances.

Along with its main function, O-rings allow to achieve high resistance to tensile loads occurring during operation due to soil shifts vertically and horizontally.

Storage rules and transport features

Each sewer pipe PVC 110 mm must be delivered to the place of work intact. This can be done subject to the basic rules of transportation. If the products will be installed after some time, it is also necessary to provide acceptable conditions for their storage:

Sewer pipes PVC 110 mm: internal

  1. Elements should be placed on a flat surface. From the bottom, wooden bars should be placed every 100 cm. Factory packaging is best removed immediately before installation.
  2. When transporting products that are not fastened together, it is required to install additional supports on each side in increments of not more than 200 cm.
  3. When manually unloading the pipe, it is recommended to remove it from the machine in a horizontal position. It is not allowed to pull them off at one end. Particular care must be taken if the outside temperature is below zero.

Final part

Although the 110 mm PVC sewer pipe is actively used in the installation of individual systems, this does not mean that it cannot be used in the construction of industrial and commercial building networks. However, such a diameter in this case is only suitable for organizing internal wiring. To drain wastewater outside the building, elements with a large cross section are usually laid, providing better throughput.

Source: https://habr.com/ru/post/C32437/