Waterproofing materials during construction work are very popular among private and professional consumers. Today they are on sale in a wide range. Among others, it is worth highlighting the material “Drain”, which is produced under the brands “Glims” and Ivsil.

High adhesion and vapor permeability can be highlighted as advantages. After drying, the layer acquires weather resistance and high resistance to frost. You can familiarize yourself with the material in more detail by reading the reviews, as well as recommendations for use.

Areas of use

waterproofing waterproofing

"Water Stop" - waterproofing, which is a dry composition based on cement. It is used to protect buildings outside and inside, to seal tanks, pools and containers that come in contact with drinking water. The material can be used with different materials, this should include:

  • plastered surfaces;
  • a rock;
  • concrete;
  • brick.

"Drain" - waterproofing, which is popular because of its outstanding characteristics. The material is highly adhesive and has a low modulus of elasticity. After drying, the layer has high strength and is resistant to low temperatures. Structures protected in this way can be operated at temperatures ranging from -50 to +70 ° .

Key Features

glims waterproof stop coating waterproofing

The waterproofing surface remains resistant to:

  • alkalis;
  • dilute acids;
  • gasoline and oil mixtures;
  • saline solutions.

Among the additional advantages, it is necessary to highlight environmental safety and the possibility of use on wet substrates, but with the note that they should not be wet. Coating waterproofing "Vodostop" has a fairly economical consumption. With a thickness of up to 3 mm per square meter, you need only 4.5 kg.

Application features

waterproofing glims drain

Waterproofing "Glims Water Stop" should be applied to prepared surfaces that are cleaned of paint, dust, oil stains and other layers. It is important to make sure that the base is strong enough. It is necessary to apply a primer on a dry surface with a hard-bristled brush, and if the surface is wet, a dry mixture of Hydro-Seal should be rubbed into it.

"Water Stop" - waterproofing, the use of which should be carried out according to a certain technology. Thus, the solution is prepared by pouring the dry mixture into clean water. For 1 kg of powder, approximately 0.34 liters of water will be needed. If you want to shut a 20-kg bag, then it will take about 6.8 liters of liquid.

The mixer must be supplemented with a special nozzle, only after the mixture can be mixed until it reaches a consistency of uniformity. After 10 minutes, the composition again needs to be mixed, and after kneading it will remain viable for another 4 hours. You can revitalize a thickened solution by stirring; water should not be added.

Surface application

waterproofing waterproofing

"Glims Water Stop" - coating waterproofing, which should be applied with a spatula or rough brush. The thickness of the layer should not exceed 3 mm. If it is necessary to form a thicker layer, it is necessary to apply a second layer, however, this must be done in a day. They use the same technology with the third.

Each applied layer must dry before applying the next one, it will take 24 hours. A dry surface should be moistened, this will allow to identify defects. The application of layers is perpendicular to each other. For the rooms of bathrooms, 2 layers will be sufficient, but if necessary, waterproofing the pool can be applied 3. When erecting new buildings, waterproofing is applied to the outer surfaces. At the same time, the ambient temperature should not fall below +5 ° C.

Consumption Reviews

gutter waterproofing application

"Water Stop" - waterproofing, which is applied by the method of forming protection in several layers. For example, for external processing of basements and foundations, it will be necessary to apply two layers, the thickness of the first of which will be 3 mm. According to customers, in this case, the consumption per 1 m 2 will be 8 kg.

If you have to process the basement from the inside, then the 3-mm layer, according to users, will require 12 kg per square meter. For cesspools, tanks, pools and hydraulic structures, the same amount of composition will be required, while the number of layers should be equal to three.

Consumers emphasize that for tanks where oil products will be stored during operation, 8 kg per square meter of a three-millimeter layer will be needed. The latter will need two. "Drain" - waterproofing, which should not be applied to metal painted surfaces. If necessary, consumers are advised to first remove the paint.

Reviews on waterproofing "Vodostop" from the manufacturer "Ivsil"

gutter waterproofing reviews

This coating waterproofing guarantees the waterproofness of monolithic coatings. The composition contains high-quality materials, namely:

  • cement;
  • special fractionated filler;
  • polymer additives.

According to consumers, this material can be used for waterproofing cement screed, masonry, plaster and concrete. If it is supposed to apply three layers, then consumers are advised to use a brush, while when forming a protection in two layers, you should stock up with a spatula. The thickness of the first layer should not exceed 1.5 mm.

The use of waterproofing "Ivsil Vodopop"

Ivsil Water Stop - waterproofing, reviews of which were presented above and can help you make the right choice. Application of the material should be carried out on the prepared surface, which is smooth and devoid of seams, fractures and cracks.

Damage can be eliminated with a special solution “Hydro-seal”. The strength of the base should be 15 MPa. If we are talking about surfaces made of concrete and brick, then they must be maintained for three months. If you plan to use a putty knife when applying, then 1 kg of dry mix will need 0.22 liters of water. Whereas when using a brush or brush, 1 kg of the composition will need 0.25 liters of water.

Each subsequent coat is applied on a moist surface that is not completely dry. To apply the following coatings, the waterproofing layer must dry, it can take up to two days. The layer thickness is determined depending on the purpose of the room. If the humidity level is increased, as well as a high probability of leakage, the layer thickness may vary from 1 to 2 mm. If the room is sufficiently wet, and the waterproofing surfaces will constantly come into contact with water, but without pressure, then the layer thickness should be increased to 3 mm. This applies to small fountains and showers.

Conclusion

Protecting a building from moisture can be difficult. This task can be considered responsible. For its implementation, only the best materials are selected that can exclude contact of surfaces with moisture.

The waterproofing described above is suitable for operations that require increased attention and control. As a result, you can get a perfectly flat surface, which will not require additional intervention during operation.