If you are the owner of a house that is not connected to the central system, then you probably already managed to face the problem of independent individual heating. A special boiler copes perfectly with the described task. The main thing is to choose the right equipment so that the family nest is cozy and warm.

Varieties of heating boilers and their characteristics

If you are interested in the Beretta boiler, then you should know that such devices are available for sale in several varieties. They can be distinguished from each other by the source of energy and the method of installation. Among other things, it is worth highlighting gas boilers, which are the most common. They are used in an amount of 70% of the total number of boilers. This is due to the low cost of gas and the prevalence of gas pipelines. Such boilers can be divided into floor and wall. The latter variety has a circulation pump and an expansion tank, which saves space in the room.

cauldron of beret

Wall-mounted boilers are double-circuit and single-circuit. If you decide to choose a double-circuit boiler "Beretta", you can provide heating for the house and use the opportunity to heat water. This equipment is small and excellent for private homes, due to the ease of installation, operation and maintenance. If it is necessary to heat the coolant without using a heating system, consumers choose single-circuit boilers.

Characteristics of floor boilers

Floor boiler "Bereta" implies the need to comply with the norms and requirements of the gas service. It operates on the basis of a cast iron and steel heat exchanger. Such equipment is floor boilers that have inflatable and atmospheric burners. The first option is characterized by ease of use, costs less, and does not cause strong noise during operation. Atmospheric burners have a high efficiency, but are more expensive.

floor gas boilers

Buying a Beretta boiler, which is equipped with an inflatable burner, you get equipment that has many advantages. Among them, one can single out the option of installing burners that can operate both on diesel fuel and gas.

Characteristics of diesel and solid fuel boilers

The first type of equipment has the main feature, which is expressed in a replaceable burner. If you replace this element, you can use a different type of fuel. Such installations are equipped with an open combustion chamber, operate on the same heating circuit, and they can be purchased exclusively in the floor version.

The Beretta boiler, the installation instructions for which will be presented below, can be solid fuel. These devices are the most common and oldest among other types of equipment. Such units are installed to maintain a warm climate and water heating in country houses and industrial complexes.

gas boiler malfunctions

This type of boiler is used in buildings that are significantly removed from the city. Units are also good because they work autonomously and are not dependent on electricity.

Description of electric boilers

Electric boiler "Beretta-Chao" does not imply special permission and approval for use in a private home. The main differences are temperature programmers and built-in equipment. Electric boilers are used as tanks for solid fuel units, if the firewood has burned out.

Such a scheme is convenient in a small heated area where it is not possible to use a solid fuel boiler with a volumetric furnace. Among other things, such installations are relevant in places where it is not possible to use gas.

Description of universal boilers

The Beretta City boiler belongs to the universal variety of equipment described in the article. The main difference is the ability to use several types of fuel at once. The basis of the work is the use of solid fuels, while other types can be used as a supplement.

Beretta boiler 24

We are talking about electricity, gas and liquid fuel. This feature allows you to operate such installations in the area under different conditions.

Design features of universal boilers

The boiler "Beretta-24" universal has a minimum configuration, which involves the presence of a water jacket, a housing, as well as a combustion chamber. In the role of additions can be automation, thermostat, pump, as well as a security system. As a rule, there is no burner in the kit, and the consumer will have to purchase it additionally.

If you decide to choose the Beretta universal wall-mounted boiler, you should know that its body can be made of cast iron or steel. As practice shows, owners often resort to repairing such boilers, in this case we are talking about a cast-iron version of the device. Among other things, cast iron is heavier than steel.

Recommendations for installing gas boiler equipment

In order to prevent gas boiler failures ahead of time, you should be guided by the rules recommended by the manufacturer during the installation of such devices. The heating system should be pressurized to an indicator of P = 1.8 atm. The master must check all connections for leaks. A voltage regulator must be installed for the boiler. Experts recommend additionally purchasing and installing an uninterruptible power supply.

Beretta boiler instruction

It is important to remember that in no case should you add antifreeze to the warming water. This may damage the gasket. In the simplest case, the consequences are leaks in the heating system.

Installation requirements

Failures of a gas boiler in most cases, consumers manage to solve on their own, as they are displayed on the equipment display. However, in order to eliminate unpleasant consequences during operation, you should use the recommendations that should be considered when carrying out installation work. Thus, it is important to properly prepare the room where the boiler will be located. Its area should not be less than 4 square meters, the height of the ceilings should be equal to 2.5 meters or more. The door that leads to the room must have a minimum width of 80 centimeters. The equipment should be illuminated in a natural way, therefore it is necessary to ensure the presence of a window opening: 0.3 square meters of its area should be for every 10 square meters of the room.

Cauldron of Beretta City

When floor gas boilers are installed, you should definitely worry about intensive ventilation of the room. This is due to the fact that gas combustion is ensured by the influx of fresh air. Oxygen flows from outside must enter the room through openings with an area of ​​8 square centimeters per 1 kilowatt of equipment power. When equipping a gas pipeline, metal should be used exclusively. As for flexible hoses, they can only be used to connect individual devices. When floor standing gas boilers are mounted, the chimney cross-section must correspond to the power characteristics of the unit. If this parameter is 30 kilowatts, then the diameter should be 130 millimeters. With an increase in equipment power up to 40 kilowatts, the diameter should be equal to 170 millimeters.

Additional recommendations for installation work

In no case should it be allowed that the cross-sectional area of ​​the chimney is less than the indicator inherent in the connection hole. The chimney must be removed above the ridge by 0.5 meters, this figure is minimal. The power supply to the boiler must be supplied with automation with adjusted current and thermal protection. In order to prevent gas leakage, it is necessary to install a gas analyzer in the room, which has an electric valve that timely shuts off the gas supply.

Cauldron Beretta Chao

The basement can be equipped with a boiler room only if it is a single-family house for private use. In the case of multi-unit multi-story buildings, installation work that involves the installation of a boiler should not be carried out in the basement.

Conclusion

If you decide to choose a wall-mounted gas boiler, then its installation can be carried out with the aim of equipping an autonomous heating system of a building with central heating. To do this, you need to have a gas main and a room, which must meet certain standards and requirements. Only in this way will it be possible to ensure not only the effective operation of the equipment, but also the safe functioning of the device. After all, the rules are not dictated by the bureaucracy, but by the sad experience of using gas boilers.